# NUT (Network UPS Tools) configuration
# See: https://networkupstools.org/docs/man/upsmon.conf.html
# UPS definition
# --------------
# Logical name of the UPS as referenced everywhere (ups.conf section, upsmon
# MONITOR line, nut_exporter ?ups= query parameter).
nut_ups_name: eaton
# Human-readable description (shown in upsc output).
nut_ups_description: "EATON Ellipse 1600"
# Driver to use. usbhid-ups covers all USB HID-compliant UPSes (EATON, APC,
# CyberPower, etc.). See: https://networkupstools.org/stable-hcl.html
nut_ups_driver: usbhid-ups
# USB vendorid filter (EATON = 0463). Helps disambiguate if multiple USB HID
# devices are present. Leave empty to auto-detect.
nut_ups_vendorid: "0463"
# Driver polling interval in seconds. Some Eaton/MGE units lock up if polled too
# aggressively (the default is 2). 10-15s gives the microcontroller breathing room.
nut_ups_pollinterval: 15
# Number of connection attempts before the driver gives up. If the USB chip
# freezes, the driver will try to reopen the port up to this many times.
nut_ups_maxretry: 3
# upsd server
# -----------
# Bind addresses for upsd. Keep localhost-only unless you want to monitor from
# other hosts (in which case add the wireguard IP and adjust firewall).
nut_upsd_listen:
- { addr: "127.0.0.1", port: 3493 }
# Local monitor user used by upsmon and nut_exporter. Password must be set.
nut_monitor_user: monitor
# nut_monitor_password: "" # Intentionally undefined - role will fail if not set
# upsmon (shutdown manager + NOTIFYCMD dispatcher)
# ------------------------------------------------
# Battery charge percentage below which an early shutdown is triggered, even if
# the UPS has not yet asserted LOWBATT. Set to 0 to rely solely on LOWBATT.
nut_upsmon_minsupplies: 1
nut_upsmon_pollfreq: 5 # seconds between polls when on line power
nut_upsmon_pollfreqalert: 5 # seconds between polls when on battery
nut_upsmon_deadtime: 15 # seconds before declaring a UPS dead
nut_upsmon_hostsync: 15 # seconds to wait for slaves before shutting down
nut_upsmon_finaldelay: 5 # seconds between SHUTDOWN notification and poweroff
# Command run on the host once the master decides it is time to power off.
# systemctl poweroff is sufficient for a single-host standalone setup.
nut_upsmon_shutdown_cmd: "/usr/bin/systemctl poweroff"
# ntfy notifications
# ------------------
# Topic to publish UPS events to. Should be a dedicated topic for power events.
# nut_ntfy_topic: "" # Intentionally undefined - role will fail if not set
nut_ntfy_server: https://ntfy.jokester.fr
# nut_ntfy_token: "" # Intentionally undefined - unauthenticated if not set
# Path of the deployed NOTIFYCMD wrapper.
nut_notify_script_path: /usr/local/bin/ups-notify